HPE QSFP+ Transceivers provide high‑density 40Gb connectivity for modern data centers, delivering reliable performance, low power consumption, and seamless integration with HPE servers, switches, and interconnects.
HPE QSFP+ Transceivers enable standards‑based 40Gb Ethernet deployment across HPE networking and compute platforms. Models such as the 40Gb QSFP+ MPO SR4 (720187‑B21) and 40Gb QSFP+ Bidirectional (841716‑B21) provide flexible optical options for leaf–spine fabrics and blade enclosure networks. Validated interoperability and HPE Services support ensure consistent performance and streamlined lifecycle management.
Overview
Models | |
| HPE BladeSystem c-Class 40Gb QSFP+ MPO SR4 100m Transceiver | 720187-B21 |
| HPE 40Gb QSFP+ Bidirectional Transceiver | 841716-B21 |
Service and Support
For the most up-to-date information on HPE Services, please refer to the HPE Services – Supplemental QuickSpecs, which provides a comprehensive and regularly updated overview of available services.
Technical Specifications
| HPE BladeSystem c-Class 40Gb QSFP + MPO SR4 100m Transceiver (720187-B21) | Notes: A 40-Gigabit transceiver in QSFP+ form-factor that supports the 4x10-Gigabit SR standard, providing 40-Gigabit connectivity up to 100m on multimode fiber. | ||
| Ports | 1 MPO 40-GbE port (IEEE 802.3ba Type 40Gbase-SR4) | ||
| Connectivity | Connector type | MPO | |
| Wavelength | 850 nm | ||
| Physical characteristics | Dimensions | 5.19(d) x 0.72(w) x 0.54(h) in. (13.18 x 1.835 x 1.371 cm) | |
| Weight | 0.08 lb. (35 g) | ||
| Transceiver form factor | QSFP+ | ||
| Environment | Operating temperature | 32°F to 158°F (0°C to 70°C) | |
| Operating relative humidity | 0% to 85%, noncondensing | ||
| Nonoperating/Storage temperature | −40°F to 185°F (−40°C to 85°C) | ||
| Electrical characteristics | Voltage supply | 3.3 V | |
| Power consumption maximum | 1.5 W | ||
| Cabling | Cable type | OM3, OM4 | |
| Cable length | Up to 100 m (OM3); up to 150 m (OM4) | ||
| Fiber type | Multimode | ||
| Notes | For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended. | ||
| Services | Refer to the Hewlett Packard Enterprise website at: http://www.hp.com/services/bladesystem for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office. | ||
| HPE BladeSystem c-Class 40Gb QSFP + MPO SR4 300m Transceiver (747698-B21) | Notes: A 40-Gigabit transceiver in QSFP+ form-factor that supports the 4x10-Gigabit SR standard, providing 40-Gigabit connectivity up to 300m on using standard MPO connector with multimode fiber. | ||
| Ports | 1 MPO 40-GbE port (IEEE 802.3ba Type 40Gbase-SR4) | ||
| Connectivity | Connector type | MPO | |
| Wavelength | 850 nm | ||
| Physical characteristics | Dimensions | 5.19(d) x 0.72(w) x 0.54(h) in. (13.18 x 1.835 x 1.371 cm) | |
| Weight | 0.08 lb. (35 g) | ||
| Transceiver form factor | QSFP+ | ||
| Environment | Operating temperature | 32°F to 158°F (0°C to 70°C) | |
| Operating relative humidity | 0% to 85%, noncondensing | ||
| Non-operating/Storage temperature | −40°F to 185°F (−40°C to 85°C) | ||
| Electrical characteristics | Voltage supply | 3.3 V | |
| Power consumption maximum | 1.5 W | ||
| Cabling | Cable type | OM3, OM4 | |
| Cable length | Up to 300 m (OM3); up to 400 m (OM4) | ||
| Fiber type | Multimode | ||
| Notes | For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended. | ||
| Services | Refer to the Hewlett Packard Enterprise website at: https://www.hpe.com/us/en/services/operational.html for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office. | ||
| HPE BladeSystem c-Class 4x10G QSFP + MPO SR4 100m Transceiver (805755-B21) | Notes: A 40-Gigabit transceiver in QSFP+ form-factor that provides 4x10Gb connections using MPO to 4x10Gb LC Breakout Cable. This transceiver is designed only for use with HPE Virtual Connect FlexFabric 20/40 F8 Module. | |
| Ports | 1 MPO 40-GbE port (IEEE 802.3ba Type 40Gbase-SR4) | |
| Connectivity | Connector type | |
| Wavelength | ||
| Physical characteristics | Dimensions | |
| Weight | ||
| Transceiver form factor | ||
| Environment | Operating temperature | |
| Operating relative humidity | ||
| Non-operating/Storage temperature | ||
| Electrical characteristics | Voltage supply | |
| Power consumption maximum | ||
| Cabling | Cable type | |
| Cable length | ||
| Fiber type | ||
| Notes | For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended. | |
| Services | Refer to the Hewlett Packard Enterprise website at: https://www.hpe.com/us/en/services/operational.html for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office. | |
| HPE BladeSystem c-Class 4x10G QSFP + MPO SR4 100m Transceiver (805755-B21) | Notes: A 40-Gigabit transceiver in QSFP+ form-factor that provides 4x10Gb connections using MPO to 4x10Gb LC Breakout Cable. This transceiver is designed only for use with HPE Virtual Connect FlexFabric 20/40 F8 Module. | ||
| Ports | 1 MPO 40-GbE port (IEEE 802.3ba Type 40Gbase-SR4) | ||
| Connectivity | Connector type | MPO | |
| Wavelength | 850 nm | ||
| Physical characteristics | Dimensions | 5.19(d) x 0.72(w) x 0.54(h) in. (13.18 x 1.835 x 1.371 cm) | |
| Weight | 0.08 lb. (35 g) | ||
| Transceiver form factor | QSFP+ | ||
| Environment | Operating temperature | 32°F to 158°F (0°C to 70°C) | |
| Operating relative humidity | 0% to 85%, noncondensing | ||
| Non-operating/Storage temperature | −40°F to 185°F (−40°C to 85°C) | ||
| Electrical characteristics | Voltage supply | 3.3 V | |
| Power consumption maximum | 1.5 W | ||
| Cabling | Cable type | OM3, OM4 | |
| Cable length | Up to 100 m (OM3); up to 150 m (OM4) | ||
| Fiber type | Multimode | ||
| Notes | For fiber patch cords, use Ultra Physical Contact (UPC) surface termination/polish. Angled Physical Contact (APC) is not recommended. | ||
| Services | Refer to the Hewlett Packard Enterprise website at: https://www.hpe.com/us/en/services/operational.html for details on the service-level descriptions and product numbers. For details about services and response times in your area, please contact your local Hewlett Packard Enterprise sales office. | ||
Summary of Changes
| Date | Version History | Action | Description of Change |
|---|---|---|---|
| 20-Jul-2026 | Changed | Service and Support Section was updated. | |
| 16-Feb-2026 | Changed | New branding applied to document. | |
| 04-Dec-2023 | Changed | Service and Support Section was updated. | |
| 15-Nov-2021 | Changed | Service and Support Section was updated. | |
| 06-May-2019 | Changed | Technical Specifications section was updated. | |
| 05-Feb-2018 | Changed | Technical Specifications section was updated. | |
| 31-Mar-2016 | Changed | Overview and Technical Specifications section were updated. | |
| Added | SKU added in Overview section: 841716-B21. | ||
| 11-Dec-2015 | Changed | Technical Specifications section was updated. QuickSpecs title was updated. | |
| 28-Sep-2015 | Changed | Overview and Technical Specifications sections were updated. | |
| 10-Jun-2014 | New | New QuickSpecs. |
© Copyright 2026 Hewlett Packard Enterprise Development LP. The information contained herein is subject to change without notice. The only warranties for Hewlett Packard Enterprise products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Hewlett Packard Enterprise shall not be liable for technical or editorial errors or omissions contained herein.