- Installation and deployment of ClusterStor L300 and L300N systems with SSU configuration and ESUs
- High Availability:
- SSU Node Failover/Failback
- SMU Node Failover/Failback
- Standard 2U MMUs or optional 4U AMMU Node Failover/Failback
- Dual Management Network Switch Redundancy (DMN)
- Lustre 2.7, based on Intel Enterprise Edition Lustre (IEEL) 2.7
- InfiniBand
- OS: CentOS Linux 7.2
- CSCLI – ClusterStor Command Line Interface
- CSM – ClusterStor Manager 3.0.0
- Supported browsers: Chrome, FireFox, Safari, and Internet Explorer 11, for Windows, Linux, and MacOS
- Support File Bundle Collection
- Split SMU/MMU (or optional AMMU) architecture that combines to make a CMU
- Optional Advanced Metadata Management Unit (AMMU) as a replacement for the base MMU
- Support for GOBI OneStor USM stx_package-3.0-1.36.8
- Mellanox IB EDR capabilities
- Mellanox SB7790 EDR Switches
- High-Speed Local Data Network (LDN) Interface:
- Mellanox CX-4 – EDR / FDR HCAs
- Mellanox CX-4 IB EDR/100GbE HCAs
- Next generation Embedded Application Controller (EAC) platform using Intel Haswell and Broadwell CPUs
- RAID Stack: Updates to optimize GridRAID and SCSI performance
- Support for 4K Native and SED Hard Drives
- Support for 10K RPM HPC Drive
- Support for 10TB Drives
- Drives: All 4K Native, T10-PI Format Type2, SED, Non-SED, and FIPS supported
Drive Model SSD / RPM Capacity Seagate ST900MM0038 10K 900GB Seagate ST300MP0075 15K 300GB Seagate ST10000NM0016, ST10000NM0086, ST10000NM0096, ST10000NM0216, and ST10000NM0226 7K 10TB Seagate ST4000NM0031 10K 4TB Seagate ST4000NM0074 7K 4TB Seagate ST6000NM0074 7K 6TB Seagate ST8000NM0095 and ST8000NM0125 7K 8TB Seagate ST800FM0053 and ST800FM0043 SSD 800GB Seagate ST800FM0183 SSD 800GB - RAS features:
- RAS Infrastructure: CLI, Nagios and Ganglia plugins, REST API
- Guided Walkthrough Repairs: 2U24 / 4U24 / 5U84 Drives, 2U24 / 4U24 PCMs, 5U84 cooling module
- Fault Isolation: 5U84 cooling module, 2U24 / 5U84 I/O controllers
- Standard MMU Addition Procedure
NOT Supported in ClusterStor 3.0.0
- CNG
- LMT (Lustre monitoring tool); replaced by CSM 3.0.0.