Qualified Functionality in Sonexion 3.1
What functions are supported or not supported in Sonexion software version 3.1
- Installation and deployment of systems with SSU configuration and ESUs, with any combination of the following storage building blocks:
- SSU
- SSU+1, SSU+2, SSU+3
- L300F
- High Availability:
- SSU node failover/failback
- SMU node failover/failback
- 2U MMU node failover/failback or optional 4U AMMU node failover/failback
- Dual Management Network (DMN) switch redundancy
- Lustre 2.11, with the following supported features:
- LockAhead (2.11)
- Progressive File Layouts (PFL) (Lustre 2.10)
- Project Quotas (Lustre 2.10)
- Large Bulk I/O (2.9)
- Subdirectory Mounts (Lustre 2.9)
- Multiple modify RPCs per-client (2.8)
- Online lfsck (Phase 4 w/ improved performance) (Lustre 2.8)
- O/S: CentOS 7.2 Linux base, plus CentOS 7.4 updates to address Spectre/Meltdown
- Support for sharing Brocade/Ruckus ICX6610 management switches with Cray clusters
- Local Data Network (LDN)
- InfiniBand EDR, FDR, QDR
- Support for Bonded Ethernet (active/passive, active/active )
- Omni-Path
- CSCLI - Sonexion Command Line Interface
- Sonexion System Manager (CSSM) browser-based GUI
- Supported browsers: Chrome, FireFox, Safari, Microsoft Edge, and Internet Explorer 11, for Windows, Linux, and MacOS
- Support File Bundle Collection
- Lustre file system with 2 storage tiers (flash and disk, L300F only)
- NXD I/O acceleration function (L300N only)
- RAID Stack: Updates to optimize GridRAID and SCSI performance
- Spectre and Meltdown security updates
- Support for GOBI OneStor USM
- Automated HDD and SSD firmware updates
- System Updater for providing basic rolling updates. Roll backs not supported. (Find more System Updater content in the ClusterStorâ„¢ Field Installation Guide (3.1) H-6163 at http://pubs.cray.com.)
- Support for 3.1 on CS9000 and Sonexion 2000 GridRAID systems (CNG not supported), via CUP from 2.0 to 3.1.
- RAS features:
- RAS Infrastructure: CLI, Nagios and Ganglia plugins, REST API
- Guided Walkthrough Repairs: 2U24 / 4U24 / 5U84 Drives, 2U24 / 4U24 PCMs, 5U84 cooling module
- Fault Isolation: 5U84 cooling module, 2U24 / 5U84 I/O controllers
- Support for AMMU PSU failures
- Support for AMMU internal HDD
Hardware
- System Management Unit (SMU)
- Metadata Management Unit (MMU):
- MMU Addition procedure
- Optional Advanced Metadata Management Unit (AMMU) as a replacement for the base MMU:
- Support for up to 2 AMMUs in a system
- AMMU Addition procedure
- Scalable Storage Unit (SSU):
- Support for 2 or 4 SSDs in each SSU
- SSU Addition procedure
- L300F:
- 2U24 enclosure with 24 SSDs
- L300F Addition procedure
- Embedded Application Controller (EAC) platform using Intel CPUs
- LDN interface:
- Mellanox CX-4 - EDR / FDR HCAs
- Mellanox CX-4 IB EDR/100GbE HCAs
- Intel Omni-Path 100 HCAs
- Disk drive support (dependent on installed drive model):
- Hard disk drive (HDD) capacities: 300GB up to 10TB
- Solid state drive (SSD) capacities: 100GB up to 3.2TB
- Drive capabilities:
- L300, L300N, Sonexion 3000, 3000T: 4K Native, T10-PI Format Type2, SED, and FIPS
- CS9000, Sonexion 2000: 4K Native, 512e, T10-PI Format Type2, SED, Non-SED, and FIPS
Features NOT Supported in Sonexion 3.1
- Lustre features not supported:
- Multi-rail LNET (Lustre 2.10)
- Data on Metadata (DoM) (Lustre 2.11)
- File Level Redundancy (FLR) (Lustre 2.11)
- Dynamic LNet Config (Lustre 2.11)
- DNE phase 2 in Lustre is experimental and not enabled by default.
- UID/GID Mapping (Lustre 2.9) is experimental
- Encrypted Data at Rest Key Management
- Installing the software release via the System Updater to an OEM server
- CIFS/NFS Gateway (CNG)
- SELinux preliminary client support